ver : d_1 update : 2011.12.08 ac-dc medical msc-e1 series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. ( single output ) msc-3.3s-e1 msc-5s-e1 msc-9s-e1 msc-12s-e1 msc-15s-e1 msc-24s-e1 max output wattage ( w ) 26.4w 40w 40w 40w 40w 40w voltage (v.dc.) 3.3v 5v 9v 12v 15v 24v current (ma) max 8000 8000 4444 3333 2666 1667 voltage set accuracy 2% 2% 2% 2% 2% 2% line regulation (typ.) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% load regulation (1-100%) (typ.) 1% 1% 1% 1% 1% 1% minimum load 1% 1% 1% 1% 1% 1% efficiency (typ) 76% 79% 82% 83% 83% 83% output capacitor load (max.) 70000 uf 33000 uf 10000 uf 4000 uf 3000 uf 1200 uf model no. ( dual output ) msc-5d-e1 msc-12d-e1 msc-15d-e1 max output wattage ( w ) 40w 40w 40w output 1 output 2 output 1 output 2 output 1 output 2 voltage (v.dc.) +5v -5v +12v -12v +15v -15v current (ma) max 4000 4000 1666 1666 1333 1333 voltage set accuracy 2% 2% 2% line regulation (typ.) 0.5% 0.5% 0.5% load regulation (10-100%) (typ.) 1% (symmetric l oad) 1% (symmetric load) 1% (symmetric load) cross regulation (typ.) 5% 5% 5% minimum load 10% 10% 10% efficiency (typ) 80% 83% 83% output capacitor load (max.) 6000 uf 1000 uf 2000 uf model no. ( dual output ) msc-5s12s-e1 msc-5s24s-e1 max output wattage ( w ) 40w 40w output 1 output 2 output 1 output 2 voltage (v.dc.) 5v 12v 5v 24v current (ma) max 5000 1250 5000 625 voltage set accuracy 3% 5% 3% 5% line regulation (typ.) 0.5% 5% 0.5% 5% load regulation (10-100%) (typ.) 2% (symmetric load) 6% (s ymmetric load) 2% (symmetric load) 6% (symmetric load) cross regulation (typ.) 1% 7% 1% 7% minimum load 25% 25% efficiency (typ) 80% 80% output capacitor load (max.) 15000 uf / 750 uf 15000 uf / 200 uf key features ? switching power modules for pcb mounting ? fully encapsulated plastic case ? universal input range 90-264vac, 47-440 hz ? regulated output ? low ripple and noise ? isolation class ii ? ce, cb, ul, cul, approvals ? 3-years product warranty
ver : d_1 update : 2011.12.08 ac-dc medical msc-e1 series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- model no. ( triple output ) msc-5s12d-e1 msc-5s15d-e1 max output wattage ( w ) 40w 40w output 2 output 3 output 1 output 2 output 3 voltage (v.dc.) +12 -12 5 +15 -15 current (ma) max 600 600 5000 500 500 voltage set accuracy 5% 3% 5% line regulation (typ.) 5% 0.5% 5% load regulation (25-100%) (typ.) (symmetric load) 7% 3% 7% cross regulation (typ.) 7% 3% 7% minimum load 25% 25% efficiency (typ) 79% 79% output capacitor load (max.) 18000 uf / 150 uf 18000 uf / 400 uf voltage 90-264 vac or 100-375 vdc frequency (hz) 47-440 hz current (full load) 860 ma max. (115 vac) / 460 ma max. (230 vac) inrush current (<2ms) 23 a max. (115 vac) / 46 a max. (230 vac) leakage current 0.1 ma max. (115 vac) / 0.2 ma max. (230 vac) input external fuse (recommend) 3.15 a slow blow type ripple & noise 3.3v 50mv of vout 5v~24v 1% of vout hold-up time 18 ms min. output switching frequency 132 khz over current protection above 105% rated output power over voltage protection zener diode clamp short circuit protection hiccup mode, indefinite (automatic recovery) protection otp 100c isolation input-output (v.ac) 4000v operating temperature -40c?+70c (case temperature max. +95c) storage temperature -40c?+85c temperature coefficient 0.01%/c humidity 95% rh environment mtbf 200,000 h~400,000 h @ 25c dimension (l x w x h) 3.5 x 2.5 x 1.06 inches ( 89.0 x 63.5 x 27.0 mm ) tolerance 0.5 mm case material plastic resin + fiberglass (flammability to ul 94v-0) weight 280 g physical cooling method free air convection class ii to iec / en 60536 approval cul / ul / cb / ansi/aami es 60601-1: 2005, 1st edition and can/csa-c22.2 no. 60601-1:08, 2nd edition, mopp emi en 55011 class b emc standards en60601-1-2 esd susceptibility en60601-1-2 radiated susceptibility en60601-1-2 eft / burst en60601-1-2 surge en60601-1-2 conducted susceptibility en60601-1-2 safety & emc safety approvals en60601-1 1. all specifications valid at normal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured at 20mhz of bandwidth with 0.1 f & 47 f parallel capacitor.
ver : d_1 update : 2011.12.08 ac-dc medical msc-e1 series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ( top view ) block diagram derating pin# single dual 5s/12s 5s/24s triple 1 ac in (l) ac in (l) ac in (l) ac in (l) 2 ac in (n) ac in (n) ac in (n) ac in (n) 3 +dc out +dc out +out2 +dc out 4 no pin no pin +out1 +5v 5 -dc out common +out2 rtn common 6 no pin no pin +out1 rtn +5 rtn 7 no connect -dc out no pin -dc out
|